A 50 m loop driven at 15 A gives a 117,810 A.m2 moment; the 40 S target decays with a 0.50 ms time constant, separating it from the host decay at late times.
Transmitter moment
117,810 A.m2
Target time constant
0.503 ms
Depth @ 1 ms
511 m
Depth @ 10 ms
1,615 m
Host conductivity
5 mS/m
Decay curve
The conductor departs from the host t^-5/2 decay at late times - that departure is the target.
Diffusion depth vs time
The smoke-ring depth tells you which time gate senses which depth.